{"product_id":"micsig-cp2100a-cp2100b-ac-dc-current-probes-2-5mhz-10a-100a-maximum-measurable-current-100apk-70-7arms-dc-acpk-356","title":"Micsig CP2100A CP2100B AC\/DC Current Probes 2.5MHz 10A\/100A Maximum Measurable Current 100Apk 70.7Arms (DC+ACpk)","description":"\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\n\u003cdiv class=\"detailmodule_media\"\u003e\u003cdiv class=\"video-container-1100199624608\"\u003e\u003cdiv class=\"detail-video\" id=\"1100199624608\" data-previewurl=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/Se0e0f3bd363d4217b998d1d85b603b51z.jpg\"\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-Se342043c6a9442e7945dfe07913efb2br.webp?v=1787719378\" slate-data-type=\"image\"\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cp\u003e\u003ckse:widget data-widget-type=\"customText\" id=\"1005000020833602\" type=\"relation\"\u003e\u003c\/kse:widget\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:22px\"\u003e\u003cstrong\u003eMicsig CP2100A CP2100B AC\/DC Current Probes 2.5MHz 10A\/100A Maximum Measurable Current 100Apk 70.7Arms (DC+ACpk)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cstrong\u003eSafety Precautions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\n\u003cli\u003e\u003cp\u003e1.The measuring circuit should be CAT II 600V or below. ? Do not measure bare conductor.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e2.Do not touch the conductor under test and the sensor head while \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003emeasuring.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e3.Do not operate in wet\/damp conditions.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e4.Do not touch the instrument or the object under test with wet hands.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e5.Please use this product within the scope permitted by the terminal.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e6.Please use this product as required. ? Please ground the product through the USB power cable.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\n\u003cli\u003e\u003cp\u003eVersion ：1.0 \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eModify content：First release \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRelease time：2019.05\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eParameter：CP2100A \/CP2100B\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eBandwidth：DC~800KHz（CP2100A）\/ DC~2.5MHz（CP2100B）\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRise time： ≤583ns（CP2100A）\/ ≤175ns（CP2100B）\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRanges ：10A\/100A（Optional on the switch）\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOutput sensitivity ：0.1V\/A (10A) \/0.01V\/A (100A)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDC accuarcy(typical) ：3%±50mA (10A)\/4%±50mA (100A,500mA~40Apk)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\/15% (100A, 40Apk~100Apk)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eSignal delay： \u0026lt;150ns (10A)\/ \u0026lt;200ns (100A)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDC signal linearity (typical) ：DC signal linearity, typical on page 6\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMeasuring range ：50mA~10Apk (10A)\/1A~100Apk (100A)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMaximum measurable current：100Apk, 70.7Arms (DC+ACpk)\/200Apk-pk, 70.7Arms (AC)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMaximum working voltage ：CAT III 300V CAT II 600V\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMaximum float voltage ：CAT III 300V CAT II 600V\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMaximum conductor diameter：13mm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOverload indication ：The buzzer beeping, the button light flashing\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower supply ：DC 5V\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eProbe head size： 11*6.1*2.5cm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eControl box size ：10.8*5.6*2.6cm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eLength ：228cm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eWeight ：290g\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eSingle package weight： 1000g\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eSingle package size ：29.5*23.6*5.7cm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOperating Temperature： 0°C ~50°C\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eStorage Temperature： -20°C ~80°C\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOperating Humidity ：5%~95% (0°C ~40°C, No condensation)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\/5%~65% (40°C ~50°C, No condensation)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOperating Altitude ：≤3000m\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eStorage Altitude： ≤12000m\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\u003cstrong\u003eUser Instructions：\u003c\/strong\u003e\u003c\/p\u003e\u003cul style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\n\u003cli\u003e\u003cp\u003e1.Connect the BNC of the current probe to the oscilloscope (or other instrument) and connect the USB cable to power the current probe.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e2.According to the current, select the appropriate range on the probe, the corresponding button light turns green. \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e3.Adjust the oscilloscope settings: input impedance 1MΩ; Select current or set display unit as A; Set the probe attenuation multiplier of the corresponding channel. If the probe is 100A(0.01V\/A), the oscilloscope should be 100X, if the probe is 10A(0.1V\/A), oscilloscope is 10X. \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e4.Press the auto zero button to realize the auto zero adjustment of the \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eprobe. After the zero adjustment is successful, the buzzer will beep for once. Otherwise, the “beep” sound will be 3, indicating that the zero adjustment fails; The external magnetic field may have a slight influence on the DC zero of the probe. After the zero adjustment is completed, please do not move it in a large range.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e5. Open the clamp of the current probe to clamp the conductor under test according to the direction indicated by the clamp head. Note: If the measured current flow direction is opposite to the direction indicated by the clamp head, the output is negative.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e6. Adjust the oscilloscope to get the best waveform.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003eNote: When the current exceeds the range, the buzzer will sound for a long time and the button light will flash.\u003c\/p\u003e\u003cp style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/p\u003e\u003cul style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\n\u003cli\u003e\u003cp\u003e1.During the product warranty period and under normal use, the company will be responsible for free maintenance due to the failure of the product itself due to quality problems.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e2.Please keep the product as dry, clean and tidy. \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e3.If there is dirt, use a soft cloth or sponge with alcohol to remove dirt. \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e4.Do not use water.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e5.In order to ensure the performance of the product, it is recommended to conduct an inspection or calibration once a year.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/p\u003e\u003cul style='font-family:\"Microsoft YaHei\";font-size:medium;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0)' align=\"start\"\u003e\n\u003cli\u003e\u003cp\u003e1.The CP2100 series is a current probe that can measure both DC and AC. \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e2.It is a split-type design that is small and beautiful.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e3. It uses a standard BNC interface for oscilloscopes or a multi-connector for adapters. \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e4.The maximum current that can be measured is 100Apk (70Arms); it is divided into 2 models, CP2100A measurable bandwidth range is DC~800KHz, CP2100B measurable bandwidth range is DC~2.5MHz,The CP2100 series current probe has two optional ranges: 10A and 100A . \u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e5.With automatic and manual zero adjustment, USB power supply, no additional power supply, making measurement more convenient. 6.Often used in motor drive, power frequency, inverter, power supply, avionics and other fields.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-Se2aa9d5e8b2d4e85aa6de8b483dda5e9a.webp?v=1787719376\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/S4f9bc7bd4c4d44578fb324b7a008b9c5i.webp?v=1787717802\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/S913ac4dbb27947c897ab3c5ded2eb950T.webp?v=1787717802\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/S0daa496b496e41c68fe9ec4a36d5a4cbL.webp?v=1787717802\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-Sc913888daa15480d91038b52c98a68c1f.webp?v=1787719377\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/Sb19213ac84cd481696a64501afc9c16by.webp?v=1787717802\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-Saf928e75ed204f5ea735d534c4b1d8e3k.webp?v=1787719377\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-S9eb559bdc6d548718cf8d3fc39291e00C.webp?v=1787719383\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-S9399201b555f48e99d323f0dbc0e2275h.webp?v=1787719383\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-S7bc578dd6651422583155bde3788dd42I.webp?v=1787719383\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-S62381a928f624bd6956d6ddb500e32ban.webp?v=1787719383\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-Se8a49df88c014c9eadb6ccfb7d5402c5m.webp?v=1787719384\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv class=\"emailcrm-product-video\" style=\"margin:24px auto;text-align:center;\"\u003e\u003cvideo controls playsinline preload=\"metadata\" poster=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/proengi-body-9599571165442-Sb552c9fdb44a43d29b1290a146f76cb2j.webp?v=1787719383\" aria-label=\"Micsig CP2100A CP2100B AC\/DC Current Probes 2.5MHz 10A\/100A Maximum Measurable Current 100Apk 70.7Arms (DC+ACpk)\" style=\"display:block;width:100%;max-width:960px;height:auto;margin:0 auto;\"\u003e\u003csource src=\"https:\/\/cdn.shopify.com\/videos\/c\/vp\/994c8b58f9874853b09fd1906bedfb44\/994c8b58f9874853b09fd1906bedfb44.HD-720p-1.6Mbps-92625416.mp4\" type=\"video\/mp4\"\u003e\u003c\/video\u003e\u003c\/div\u003e","brand":"MICSIG","offers":[{"title":"CP2100A","offer_id":48381882925314,"sku":"12000042794798142","price":301.57,"currency_code":"USD","in_stock":true},{"title":"CP2100B","offer_id":48381882958082,"sku":"12000042794798141","price":444.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7674\/3938\/files\/Sc06dcac09c084ad8b67a20dedae5f5ff1.webp?v=1787717802","url":"https:\/\/proengi.com\/products\/micsig-cp2100a-cp2100b-ac-dc-current-probes-2-5mhz-10a-100a-maximum-measurable-current-100apk-70-7arms-dc-acpk-356","provider":"PROENGI","version":"1.0","type":"link"}